Solar PV Battery Driven Electric Vehicle in MATLAB
Solar PV Battery Driven Electric Vehicle in MATLAB
𝐈𝐧𝐭𝐫𝐨𝐝𝐮𝐜𝐭𝐢𝐨𝐧
The Solar PV Battery Driven Electric Vehicle in MATLAB model demonstrates how a solar photovoltaic source and battery energy storage system can work together to supply a DC motor drive used as an electric vehicle load.

The model is developed in MATLAB/Simulink and combines:
Solar PV generation
Transformerless buck-boost conversion
MPPT control
Battery energy storage
Bidirectional DC-DC conversion
DC bus voltage regulation
PMDC motor drive
Solar-to-battery and battery-to-motor power management
The main objective is to extract the maximum available solar power while maintaining a regulated 90 V DC bus for reliable motor operation.
𝐒𝐲𝐬𝐭𝐞𝐦 𝐎𝐯𝐞𝐫𝐯𝐢𝐞𝐰
The complete system consists of the following major sections:
Solar PV array
Transformerless buck-boost converter
P&O MPPT controller
PWM generator
Battery bank
Bidirectional DC-DC converter
DC bus voltage controller
PMDC motor
Measurement and monitoring section
The basic power flow is:
Solar PV → Buck-Boost Converter → DC Bus → PMDC Motor
At the same time:
Battery ↔ Bidirectional DC-DC Converter ↔ DC Bus
The battery can therefore either absorb excess solar energy or supply additional power when PV generation decreases.
𝐒𝐲𝐬𝐭𝐞𝐦 𝐒𝐩𝐞𝐜𝐢𝐟𝐢𝐜𝐚𝐭𝐢𝐨𝐧𝐬
Solar PV Parameters
Parameter | Value |
Approximate PV array maximum power | 1830 W |
Single-panel maximum power | ≈ 305 W |
Open-circuit voltage | 44.8 V |
Voltage at maximum power point | 35.59 V |
Short-circuit current | 8.95 A |
Current at maximum power point | 8.57 A |
Series-connected panels | 2 |
Parallel strings | 3 |
Standard irradiance | 1000 W/m² |
Standard temperature | 25°C |
With the selected series-parallel arrangement, the PV array can generate approximately 1.83 kW under standard operating conditions.
𝐓𝐫𝐚𝐧𝐬𝐟𝐨𝐫𝐦𝐞𝐫𝐥𝐞𝐬𝐬 𝐁𝐮𝐜𝐤-𝐁𝐨𝐨𝐬𝐭 𝐂𝐨𝐧𝐯𝐞𝐫𝐭𝐞𝐫
A key feature of this model is the use of a transformerless buck-boost converter between the PV array and DC bus.
Unlike a conventional converter designed only for step-up or step-down operation, this topology can operate in both modes.
Main functions
Steps the PV voltage up when required
Steps the PV voltage down when required
Interfaces the PV array with the DC bus
Supports maximum power extraction
Responds to variations in solar irradiance
Eliminates the need for a transformer in the DC conversion stage
This makes the converter suitable for renewable-energy-fed electric drive applications where the PV operating voltage changes continuously.
𝐌𝐏𝐏𝐓 𝐂𝐨𝐧𝐭𝐫𝐨𝐥
The PV converter is controlled using a Perturb and Observe MPPT algorithm.
The controller receives:
PV voltage
PV current
From these measurements, it determines the appropriate duty cycle for the converter.
The control sequence is:
PV Voltage + PV Current → P&O MPPT → Duty Cycle → PWM Generator → Buck-Boost Converter
The MPPT controller continuously adjusts the converter operation so that the PV array operates close to its maximum power point.
Why MPPT is required
Solar PV output changes because of variations in:
Solar irradiance
Temperature
Operating voltage
Connected load condition
Without MPPT, the available solar power may not be fully utilized.
𝐁𝐚𝐭𝐭𝐞𝐫𝐲 𝐄𝐧𝐞𝐫𝐠𝐲 𝐒𝐭𝐨𝐫𝐚𝐠𝐞
The battery provides energy support whenever the PV array cannot supply the complete motor demand.
Battery information
Parameter | Value |
Battery capacity | 40 Ah |
Battery connection | Through bidirectional DC-DC converter |
Main function | Charging and discharging support |
Control objective | DC bus voltage regulation |
The battery acts as an energy buffer between the PV source and motor load.
𝐁𝐢𝐝𝐢𝐫𝐞𝐜𝐭𝐢𝐨𝐧𝐚𝐥 𝐃𝐂-𝐃𝐂 𝐂𝐨𝐧𝐯𝐞𝐫𝐭𝐞𝐫
The battery is connected to the main DC bus through a bidirectional DC-DC converter.
This converter allows current to flow in both directions.
Charging mode
When PV power is greater than the motor requirement:
PV → Motor + Battery Charging
Discharging mode
When PV generation decreases:
PV + Battery → Motor
The converter therefore performs both charging and discharging functions depending on the instantaneous power balance.
𝐃𝐂 𝐁𝐮𝐬 𝐕𝐨𝐥𝐭𝐚𝐠𝐞 𝐂𝐨𝐧𝐭𝐫𝐨𝐥
The motor drive requires a stable supply voltage. Therefore, the DC bus is regulated around:
90 V
The control system measures the actual DC bus voltage and compares it with the reference value.
The control path is:
90 V Reference → Voltage Comparison → PI Controller → Duty Cycle → PWM → Bidirectional Converter
The battery converter then charges or discharges as required to maintain the DC bus close to the reference value.
DC Bus Control Parameters
Parameter | Value |
DC bus reference | 90 V |
Controller | PI controller |
Controlled converter | Bidirectional DC-DC converter |
Main objective | Maintain stable motor supply voltage |
𝐏𝐌𝐃𝐂 𝐌𝐨𝐭𝐨𝐫 𝐚𝐬 𝐄𝐥𝐞𝐜𝐭𝐫𝐢𝐜 𝐕𝐞𝐡𝐢𝐜𝐥𝐞 𝐋𝐨𝐚𝐝
The PMDC motor represents the propulsion load of the electric vehicle.
The motor receives energy continuously from either:
Solar PV
Battery
Solar PV and battery together
Because the DC bus is regulated, the motor can continue operating even when solar irradiance changes.
The model monitors:
Motor speed
Electromagnetic torque
Motor current
𝐖𝐨𝐫𝐤𝐢𝐧𝐠 𝐏𝐫𝐨𝐜𝐞𝐬𝐬
The complete operating sequence can be understood in the following steps.
The PV array generates electrical power according to the available irradiance.
PV voltage and current are supplied to the P&O MPPT controller.
The MPPT algorithm determines the converter duty cycle.
The PWM generator produces switching pulses for the transformerless buck-boost converter.
The PV converter transfers maximum available solar power to the DC bus.
The PMDC motor draws power from the DC bus.
The DC bus voltage controller continuously monitors the 90 V bus.
Excess PV energy is directed toward battery charging.
When PV output decreases, the battery begins discharging.
The bidirectional converter maintains the DC bus close to 90 V.
The motor continues operating with comparatively stable speed, torque, and current.
𝐈𝐫𝐫𝐚𝐝𝐢𝐚𝐧𝐜𝐞 𝐓𝐞𝐬𝐭 𝐏𝐫𝐨𝐟𝐢𝐥𝐞
The simulation evaluates the system under changing solar conditions.
Simulation Time | Irradiance |
0–5 s | 1000 W/m² |
5–10 s | 500 W/m² |
10–15 s | 1000 W/m² |
This changing irradiance profile is useful for observing how the PV array, battery, DC bus, and motor respond dynamically.
𝐒𝐢𝐦𝐮𝐥𝐚𝐭𝐢𝐨𝐧 𝐑𝐞𝐬𝐮𝐥𝐭𝐬
PV Performance
At approximately 1000 W/m², the PV system operates close to its rated maximum power.
Typical observed values include:
Variable | Approximate Value |
PV voltage | Around 70 V |
PV current | Around 25 A |
PV power | Around 1.8–1.86 kW |
The MPPT controller maintains the PV operating point close to the maximum power region.
Response from 0 to 5 Seconds
During the high-irradiance condition:
PV power is high.
The PV array supplies the PMDC motor.
Excess power is available for battery charging.
Battery current becomes negative according to the selected sign convention.
Battery SOC gradually increases.
DC bus voltage remains close to 90 V.
Power flow:
PV → Motor + Battery
Response from 5 to 10 Seconds
When irradiance decreases to approximately 500 W/m²:
PV power drops to roughly 900–950 W.
The PV source alone is no longer sufficient to meet the complete motor demand.
Battery current changes from negative to positive.
The battery enters discharging mode.
Battery SOC begins to decrease.
The battery supplies the power deficit.
DC bus voltage remains regulated close to 90 V.
Power flow:
PV + Battery → Motor
This demonstrates the role of battery storage in maintaining uninterrupted motor operation during reduced solar generation.
Response from 10 to 15 Seconds
When irradiance returns to 1000 W/m²:
PV power increases again to approximately 1.8 kW.
The PV system once again supplies the motor load.
Additional available energy charges the battery.
Battery current becomes negative.
Battery SOC begins increasing.
Motor operation remains stable.
Power flow:
PV → Motor + Battery Charging
𝐁𝐚𝐭𝐭𝐞𝐫𝐲 𝐎𝐩𝐞𝐫𝐚𝐭𝐢𝐧𝐠 𝐌𝐨𝐝𝐞𝐬
Operating Condition | Battery Current | Battery Mode | SOC Trend |
PV power greater than load demand | Negative | Charging | Increasing |
PV power lower than load demand | Positive | Discharging | Decreasing |
PV output restored | Negative | Charging | Increasing |
This automatic transition between charging and discharging is one of the main advantages of the hybrid PV-battery configuration.
𝐌𝐨𝐭𝐨𝐫 𝐑𝐞𝐬𝐩𝐨𝐧𝐬𝐞
The simulation shows that the PMDC motor continues operating even during irradiance variation.
Typical observed motor performance includes:
Parameter | Approximate Behaviour |
Motor speed | Around 1700 rpm |
Torque | Maintained approximately constant after transient response |
Motor current | Remains comparatively stable |
DC supply | Maintained near 90 V |
Small transient disturbances appear when the solar irradiance changes, but the battery and DC bus controller help stabilize the motor operation.
𝐌𝐞𝐚𝐬𝐮𝐫𝐞𝐦𝐞𝐧𝐭 𝐒𝐞𝐜𝐭𝐢𝐨𝐧
The Simulink model includes dedicated measurement blocks for observing system performance.
PV Measurements
PV voltage
PV current
PV power
Battery Measurements
Battery voltage
Battery current
Battery SOC
DC bus voltage
Motor Measurements
Motor speed
Motor torque
Motor current
These signals help analyze the complete energy flow and transient behaviour of the system.
𝐂𝐨𝐧𝐭𝐫𝐨𝐥 𝐒𝐭𝐫𝐚𝐭𝐞𝐠𝐲
The model uses two important control loops.
Control Section | Controller | Main Purpose |
PV converter | P&O MPPT | Extract maximum available PV power |
Battery converter | PI voltage controller | Regulate DC bus at 90 V |
These two controllers work together to achieve both maximum renewable-energy utilization and stable motor operation.
𝐊𝐞𝐲 𝐅𝐞𝐚𝐭𝐮𝐫𝐞𝐬
Solar PV powered electric drive architecture
Battery-supported energy management
Transformerless buck-boost converter
Buck and boost operating capability
P&O MPPT control
90 V regulated DC bus
Bidirectional battery charging and discharging
Automatic response to irradiance variations
Continuous PMDC motor operation
SOC monitoring
PV, battery, DC bus, and motor measurements
Dynamic simulation under changing solar conditions
MATLAB/Simulink-based implementation
𝐀𝐝𝐯𝐚𝐧𝐭𝐚𝐠𝐞𝐬
Improves utilization of available solar energy
Maintains motor operation during reduced irradiance
Allows excess solar energy to charge the battery
Supports bidirectional battery power flow
Maintains a nearly constant DC bus voltage
Reduces dependence on a single energy source
Demonstrates practical renewable-energy integration with electric drives
Provides a useful platform for testing MPPT and energy-management concepts
𝐀𝐩𝐩𝐥𝐢𝐜𝐚𝐭𝐢𝐨𝐧𝐬
This model is useful for studying:
Solar-powered electric vehicles
PV-battery hybrid electric drives
Renewable-energy-based transportation
DC microgrid-fed motor drives
MPPT controller performance
Battery charging and discharging control
Bidirectional DC-DC converters
DC bus voltage regulation
Electric vehicle energy-management strategies
Renewable energy conversion systems
𝐖𝐡𝐚𝐭 𝐂𝐚𝐧 𝐁𝐞 𝐋𝐞𝐚𝐫𝐧𝐞𝐝 𝐅𝐫𝐨𝐦 𝐓𝐡𝐢𝐬 𝐌𝐨𝐝𝐞𝐥?
Students, researchers, and engineers can use this simulation to understand:
How PV power changes with irradiance
How MPPT extracts maximum solar power
How a buck-boost converter interfaces the PV array with a DC bus
How a battery compensates for reduced PV generation
How bidirectional converters control charging and discharging
How DC bus voltage can be maintained using PI control
How motor behaviour changes during source-side disturbances
How battery SOC varies according to charging and discharging conditions
𝐂𝐨𝐧𝐜𝐥𝐮𝐬𝐢𝐨𝐧
The Solar PV Battery Driven Electric Vehicle in MATLAB model demonstrates an effective hybrid energy system in which solar PV and battery storage jointly supply a PMDC motor.
The P&O MPPT controller extracts maximum available solar power through the transformerless buck-boost converter, while the bidirectional battery converter regulates the DC bus near 90 V.
When solar generation is high, the PV array supplies the motor and charges the battery. When solar irradiance decreases, the battery automatically provides the required additional power. As a result, the motor continues operating with stable speed, torque, and current despite changes in solar input.
This MATLAB/Simulink model provides a clear and practical platform for understanding solar PV conversion, MPPT, battery energy storage, bidirectional power flow, DC bus regulation, and electric vehicle motor operation.



Comments