Fuzzy MPPT For Solar PV Battery DC Microgrid System in MATLAB
Fuzzy MPPT For Solar PV Battery DC Microgrid System in MATLAB
𝐈𝐧𝐭𝐫𝐨𝐝𝐮𝐜𝐭𝐢𝐨𝐧
The Fuzzy MPPT For Solar PV Battery DC Microgrid System in MATLAB demonstrates a complete solar photovoltaic–battery DC microgrid developed in MATLAB/Simulink.

The system combines:
Solar PV generation
Fuzzy Logic based MPPT control
DC–DC boost converter
Battery energy storage
Bidirectional DC–DC converter
DC load
DC bus voltage control
Automatic battery charging and discharging
Variable solar irradiation testing
The main objective is to extract the maximum available power from the PV array while maintaining the DC bus voltage close to 400 V under changing solar irradiation.
The battery automatically absorbs excess PV energy or supplies the power deficit depending on the balance between PV generation and load demand.
𝐒𝐲𝐬𝐭𝐞𝐦 𝐎𝐯𝐞𝐫𝐯𝐢𝐞𝐰
The simulated DC microgrid contains two major energy sources:
Solar PV array
Battery energy storage system
The PV system is connected to the common DC bus through a boost converter.
The battery is connected through a bidirectional DC–DC converter, allowing energy flow in both directions.
The overall structure can be understood as:
Solar PV → Boost Converter → DC Bus → DC Load
and
Battery ↔ Bidirectional DC–DC Converter ↔ DC Bus
Main System Ratings
Parameter | Value / Description |
PV module power | 250 W |
Number of PV modules | 8 |
PV configuration | 8 modules in series |
Total PV rated power | Approximately 2000 W |
Standard irradiance | 1000 W/m² |
Standard temperature | 25°C |
Battery configuration | 20 × 12 V batteries in series |
Battery nominal voltage | Approximately 240 V |
Battery capacity | 48 Ah |
DC bus reference voltage | 400 V |
DC load power | Approximately 1000 W |
PV converter | Boost converter |
Battery converter | Bidirectional DC–DC converter |
MPPT method | Fuzzy Logic MPPT |
Battery-side control | DC bus voltage control |
𝐒𝐨𝐥𝐚𝐫 𝐏𝐕 𝐀𝐫𝐫𝐚𝐲
The PV array consists of eight 250 W solar modules connected in series, giving a maximum rated output of approximately:
2000 W under standard test conditions.
Solar PV output is highly dependent on:
Solar irradiation
Temperature
Operating voltage
Operating current
Because the PV characteristic is nonlinear, the maximum-power operating point changes whenever the environmental conditions change.
For this reason, the PV array cannot simply be connected to the DC bus and expected to deliver maximum power continuously.
A suitable MPPT controller is required.
𝐖𝐡𝐲 𝐅𝐮𝐳𝐳𝐲 𝐌𝐏𝐏𝐓 𝐢𝐬 𝐔𝐬𝐞𝐝
The Fuzzy MPPT controller continuously observes the PV operating condition and adjusts the boost converter duty cycle.
The main advantages of this approach include:
Fast response to changing irradiation
Good maximum power tracking capability
No requirement for an exact mathematical PV model
Suitable operation under nonlinear PV characteristics
Flexible rule-based control
Reduced dependence on fixed-step perturbation
The controller uses PV voltage and current measurements to determine the appropriate operating direction.
𝐅𝐮𝐳𝐳𝐲 𝐌𝐏𝐏𝐓 𝐈𝐧𝐩𝐮𝐭𝐬
The Fuzzy Logic controller uses information derived from the PV voltage and power.
Two important quantities are considered:
PV operating slope
Change in the slope
These parameters indicate the position of the PV operating point relative to the maximum power point.
The controller then determines how the converter duty cycle should be adjusted.
Fuzzy Controller Details
Item | Description |
Measured PV quantities | Voltage and current |
Calculated quantity | PV power |
Main fuzzy input | PV power-voltage slope |
Second fuzzy input | Change in slope |
Controller output | Duty cycle adjustment |
Fuzzy rule base | 49 rules |
Converter controlled | PV boost converter |
Switching control | PWM |
The model uses a pre-designed 49-rule fuzzy rule base containing input and output membership functions.
𝐖𝐨𝐫𝐤𝐢𝐧𝐠 𝐏𝐫𝐨𝐜𝐞𝐬𝐬
The operation of the complete system can be divided into several stages.
1. PV Voltage and Current Measurement
The PV array voltage and current are continuously measured.
These signals are used to determine the instantaneous PV power and operating condition.
2. Fuzzy MPPT Processing
The Fuzzy MPPT controller evaluates:
Present PV condition
Previous sampled condition
Variation in PV voltage
Variation in PV power
PV operating slope
Change in operating slope
Based on these quantities, the fuzzy controller determines the required converter duty cycle.
3. PWM Generation
The duty-cycle output is passed to the PWM generator.
The PWM signal controls the switching device of the PV boost converter.
4. PV Maximum Power Extraction
By continuously modifying the duty cycle, the boost converter changes the operating point of the PV array.
The controller therefore attempts to keep the PV system near its maximum power point even when irradiation changes.
5. Energy Transfer to DC Bus
The extracted PV power is transferred to the common DC bus.
The DC bus supplies the connected DC load and interacts with the battery storage system.
𝐁𝐨𝐨𝐬𝐭 𝐂𝐨𝐧𝐯𝐞𝐫𝐭𝐞𝐫
The PV array is connected to the DC bus through a DC–DC boost converter.
Its main functions are:
Interface the PV array with the higher-voltage DC bus
Control PV operating voltage
Enable MPPT operation
Transfer available PV energy to the DC bus
Respond to the duty-cycle command generated by the fuzzy controller
The switching operation of this converter is directly linked to the output of the Fuzzy MPPT controller.
𝐁𝐚𝐭𝐭𝐞𝐫𝐲 𝐄𝐧𝐞𝐫𝐠𝐲 𝐒𝐭𝐨𝐫𝐚𝐠𝐞
The battery system consists of approximately 20 batteries of 12 V connected in series.
This gives a nominal battery-bank voltage of approximately 240 V.
The stated battery capacity is 48 Ah.
The battery provides an important balancing function in the DC microgrid.
It can operate in:
Charging mode
Discharging mode
Near-idle condition
Its operating mode depends primarily on the available PV power and load demand.
𝐁𝐢𝐝𝐢𝐫𝐞𝐜𝐭𝐢𝐨𝐧𝐚𝐥 𝐃𝐂–𝐃𝐂 𝐂𝐨𝐧𝐯𝐞𝐫𝐭𝐞𝐫
The battery is connected to the common DC bus through a bidirectional DC–DC converter.
Unlike a conventional unidirectional converter, this converter permits power transfer:
From the DC bus to the battery during charging
From the battery to the DC bus during discharging
This makes the battery capable of supporting the DC load while also absorbing surplus PV power.
𝐂𝐨𝐧𝐭𝐫𝐨𝐥 𝐒𝐭𝐫𝐚𝐭𝐞𝐠𝐲
The control strategy has two major sections.
PV-Side Control
The PV-side boost converter is controlled by the Fuzzy MPPT algorithm.
Its purpose is to:
Track changing PV conditions
Adjust converter duty cycle
Extract maximum available solar power
Battery-Side Control
The bidirectional converter is controlled primarily to maintain the DC bus voltage around:
400 V
The actual DC bus voltage is measured and compared with the reference value.
The resulting control signal is processed through a controller and PWM generator to control the battery converter switches.
This allows the battery to react automatically to changes in generation and load.
𝐏𝐨𝐰𝐞𝐫 𝐁𝐚𝐥𝐚𝐧𝐜𝐢𝐧𝐠 𝐌𝐨𝐝𝐞𝐬
The operating condition of the battery depends on the relationship between PV power and load power.
PV Power Condition | Battery Mode | System Behaviour |
PV power > Load power | Charging | Excess PV power charges the battery |
PV power ≈ Load power | Near idle | PV approximately supplies the complete load |
PV power < Load power | Discharging | Battery supplies the missing load power |
This power-balancing process enables stable operation of the DC microgrid.
𝐃𝐂 𝐁𝐮𝐬 𝐕𝐨𝐥𝐭𝐚𝐠𝐞 𝐂𝐨𝐧𝐭𝐫𝐨𝐥
One of the most important requirements in a DC microgrid is maintaining a stable common bus voltage.
In this system, the target DC bus voltage is:
400 V
The battery-side converter compensates for the difference between solar generation and load consumption.
For example:
When PV generation increases, the battery absorbs excess energy.
When PV generation decreases, the battery supplies additional power.
As a result, large DC bus voltage variations are minimized.
This control approach helps create a stable electrical supply for the connected DC load.
𝐈𝐫𝐫𝐚𝐝𝐢𝐚𝐧𝐜𝐞 𝐕𝐚𝐫𝐢𝐚𝐭𝐢𝐨𝐧 𝐓𝐞𝐬𝐭
The model is tested under rapidly changing solar irradiation.
The irradiation is changed approximately every 0.3 seconds.
The test includes decreasing irradiation followed by increasing irradiation.
Irradiance Test Conditions
Test Stage | Irradiance |
Initial condition | 1000 W/m² |
Reduced condition | 800 W/m² |
Reduced condition | 500 W/m² |
Low condition | 300 W/m² |
Very low condition | Approximately 10 W/m² |
Recovery condition | 300 W/m² |
Recovery condition | 500 W/m² |
Recovery condition | 800 W/m² |
Final condition | 1000 W/m² |
This changing profile is useful for evaluating both the MPPT response and battery power-balancing performance.
𝐒𝐢𝐦𝐮𝐥𝐚𝐭𝐢𝐨𝐧 𝐑𝐞𝐬𝐮𝐥𝐭𝐬
The simulation monitors several important system quantities.
PV Measurements
The model displays:
PV voltage
PV current
PV power
As irradiation decreases, the available PV power also decreases.
When irradiation increases again, the PV output rises accordingly.
The Fuzzy MPPT controller adjusts the converter operation to follow these changing maximum-power conditions.
𝐏𝐕 𝐏𝐨𝐰𝐞𝐫 𝐔𝐧𝐝𝐞𝐫 𝐃𝐢𝐟𝐟𝐞𝐫𝐞𝐧𝐭 𝐈𝐫𝐫𝐚𝐝𝐢𝐚𝐧𝐜𝐞
The transcript indicates the following approximate operating values.
Irradiance | Approximate PV Power | Battery Behaviour |
1000 W/m² | 2000 W | Charging |
800 W/m² | 1600 W | Charging |
500 W/m² | Around 1000 W | Near balance / slight battery support |
Below 500 W/m² | Below load demand | Discharging |
Irradiance increasing again | PV power increases | Returns toward charging |
These results demonstrate the energy-balancing action of the battery.
𝐁𝐚𝐭𝐭𝐞𝐫𝐲 𝐑𝐞𝐬𝐩𝐨𝐧𝐬𝐞
At high irradiation:
PV power is greater than the DC load demand.
Excess solar energy is transferred to the battery.
Battery current indicates charging.
Battery SOC gradually increases.
At lower irradiation:
PV power becomes insufficient for the load.
The bidirectional converter reverses the power flow.
The battery supplies the missing energy.
Battery SOC gradually decreases.
Once solar generation increases again, the battery returns to charging operation.
𝐂𝐮𝐫𝐫𝐞𝐧𝐭 𝐃𝐢𝐫𝐞𝐜𝐭𝐢𝐨𝐧
In the displayed simulation results, battery current polarity can be used to identify the operating mode.
Battery Current | Operating Interpretation |
Negative current | Battery charging |
Positive current | Battery discharging |
Current close to zero | Battery nearly idle |
For example, under higher solar generation, the battery current becomes negative because the excess PV energy is being stored.
𝐃𝐂 𝐋𝐨𝐚𝐝 𝐑𝐞𝐬𝐮𝐥𝐭𝐬
The DC load is approximately:
1000 W
The simulation observes:
DC bus voltage
DC load current
DC load power
Even when PV power changes significantly due to irradiation variation, the battery-side voltage controller helps maintain the common DC bus close to 400 V.
This indicates effective coordination between renewable generation, battery storage, and load demand.
𝐒𝐎𝐂 𝐑𝐞𝐬𝐩𝐨𝐧𝐬𝐞
Battery state of charge follows the charging and discharging process.
The observed behaviour is:
SOC increases when excess PV energy is available.
SOC decreases when the battery supports the load.
SOC again increases when irradiation and PV power recover.
The SOC response therefore confirms that the bidirectional converter is correctly controlling battery energy flow.
𝐎𝐩𝐞𝐫𝐚𝐭𝐢𝐧𝐠 𝐂𝐨𝐧𝐝𝐢𝐭𝐢𝐨𝐧 𝐒𝐮𝐦𝐦𝐚𝐫𝐲
Condition | PV Generation | Load Demand | Battery |
Strong sunlight | High | Constant | Charges |
Moderate sunlight | Medium | Constant | Charging reduces |
PV approximately equals load | Balanced | Constant | Nearly idle |
Weak sunlight | Low | Constant | Discharges |
Solar power recovers | Increasing | Constant | Returns to charging |
𝐊𝐞𝐲 𝐅𝐞𝐚𝐭𝐮𝐫𝐞𝐬
2 kW solar PV system
Fuzzy Logic based MPPT
49-rule fuzzy controller
PV voltage and current feedback
Dynamic duty-cycle generation
PWM controlled boost converter
Battery energy storage
Bidirectional DC–DC converter
Automatic charging and discharging
400 V DC bus regulation
Variable irradiation simulation
PV voltage, current, and power monitoring
Battery voltage, current, and SOC monitoring
DC load voltage, current, and power monitoring
Power-balancing demonstration
MATLAB/Simulink implementation
𝐁𝐞𝐧𝐞𝐟𝐢𝐭𝐬 𝐨𝐟 𝐭𝐡𝐞 𝐏𝐫𝐨𝐩𝐨𝐬𝐞𝐝 𝐂𝐨𝐧𝐭𝐫𝐨𝐥
Efficient PV Utilization
The Fuzzy MPPT controller attempts to keep the solar array operating close to its maximum power point.
Stable DC Bus
The battery-side converter helps regulate the DC bus around the selected 400 V reference.
Automatic Power Sharing
The battery reacts automatically to the difference between PV generation and load demand.
Renewable Energy Support
Energy available during strong sunlight can be stored instead of being wasted.
Load Support
During weak solar conditions, stored battery energy can maintain power delivery to the DC load.
Dynamic Performance Testing
The irradiation profile allows the system behaviour to be studied under changing environmental conditions rather than only at one fixed operating point.
𝐀𝐩𝐩𝐥𝐢𝐜𝐚𝐭𝐢𝐨𝐧𝐬
This MATLAB/Simulink model is useful for studying:
Solar PV DC microgrids
Renewable energy control
Fuzzy Logic MPPT
Battery-integrated PV systems
DC bus voltage regulation
Bidirectional converter control
Energy storage systems
Standalone DC networks
Smart DC distribution systems
Renewable energy laboratories
MPPT algorithm analysis
Power electronic converter studies
Battery charging and discharging control
Energy-management research
𝐖𝐡𝐚𝐭 𝐂𝐚𝐧 𝐁𝐞 𝐀𝐧𝐚𝐥𝐲𝐳𝐞𝐝 𝐟𝐫𝐨𝐦 𝐭𝐡𝐞 𝐌𝐨𝐝𝐞𝐥?
Students, researchers, and engineers can use the model to analyze:
Effect of irradiation variation on PV power
Fuzzy MPPT tracking behaviour
PV operating voltage variation
PV current variation
PV power response
Boost converter switching performance
Battery charging behaviour
Battery discharging behaviour
Battery current direction
Battery SOC variation
DC bus voltage stability
DC load power
Power-sharing between PV and battery
Response of the system during sudden solar power reduction
Recovery when solar irradiation increases
𝐒𝐢𝐦𝐮𝐥𝐚𝐭𝐢𝐨𝐧 𝐒𝐢𝐠𝐧𝐚𝐥𝐬 𝐀𝐯𝐚𝐢𝐥𝐚𝐛𝐥𝐞
System Section | Signals Observed |
Solar PV | Voltage, current, power |
Battery | Voltage, current, SOC |
DC bus | DC bus voltage |
DC load | Voltage, current, power |
MPPT controller | Duty-cycle response |
Converter | PWM switching command |
Operating environment | Irradiance variation |
𝐖𝐡𝐲 𝐭𝐡𝐢𝐬 𝐌𝐨𝐝𝐞𝐥 𝐢𝐬 𝐔𝐬𝐞𝐟𝐮𝐥
This model provides a clear demonstration of how different control sections interact inside a renewable DC microgrid.
Instead of studying MPPT, battery control, and DC bus regulation separately, the model combines them in one integrated simulation.
It helps users understand:
How maximum solar power is extracted
How the battery compensates for changing PV generation
How excess renewable energy is stored
How the battery supports the load during low irradiation
How a stable DC bus is maintained
How Fuzzy Logic can be applied to nonlinear renewable-energy control
𝐂𝐨𝐧𝐜𝐥𝐮𝐬𝐢𝐨𝐧
The Fuzzy MPPT For Solar PV Battery DC Microgrid System in MATLAB demonstrates an integrated renewable-energy system combining a 2 kW solar PV array, Fuzzy MPPT controller, boost converter, battery storage, bidirectional DC–DC converter, and DC load.
The Fuzzy MPPT algorithm controls the PV boost converter to extract maximum available solar power under changing irradiation conditions. At the same time, the battery-side bidirectional converter regulates the common DC bus around 400 V.
When PV generation exceeds the approximately 1 kW load demand, the excess energy charges the battery. When PV generation becomes insufficient, the battery discharges and supplies the required additional power.
The simulation therefore provides a useful platform for understanding maximum power point tracking, battery energy management, bidirectional power flow, DC bus regulation, and renewable-energy power balancing within a solar PV battery DC microgrid.



Comments