Neural Network Control of Shunt Active Power Filter

3 days ago
6 min read

Neural Network Control of Shunt Active Power Filter


𝐈𝐧𝐭𝐫𝐨𝐝𝐮𝐜𝐭𝐢𝐨𝐧


The Neural Network Control of Shunt Active Power Filter demonstrates an intelligent power-quality improvement technique using MATLAB/Simulink. The system is designed to reduce current harmonics produced by nonlinear loads and improve the quality of the source current.


Neural Network Control of Shunt Active Power Filter

Neural Network Control of Shunt Active Filter in MATLAB
₹12,000.00₹6,000.00
Buy Now

When nonlinear loads such as a three-phase rectifier with an RL load are connected to the electrical network, the load current becomes distorted. This distortion can also affect the source current and increase harmonic pollution in the power system.

A Shunt Active Power Filter (SAPF) is connected in parallel with the system to inject a compensating current. The proposed model replaces the conventional controller used in the DC-link regulation stage with a trained neural network controller, providing improved harmonic compensation.    Pasted text

𝐒𝐲𝐬𝐭𝐞𝐦 𝐎𝐯𝐞𝐫𝐯𝐢𝐞𝐰

The MATLAB/Simulink model mainly consists of:

  • Three-phase AC grid

  • Nonlinear load

  • Three-phase voltage-source inverter

  • DC-link capacitor

  • Shunt Active Power Filter

  • Voltage and current measurement system

  • Power calculation and reference-current generation

  • Hysteresis current controller

  • Neural network controller

  • FFT and THD analysis

The active filter is connected in parallel with the nonlinear load. Its main purpose is to generate the required compensation current so that harmonic components drawn by the nonlinear load are prevented from significantly appearing in the grid current.    Pasted text

Main System Details

Parameter / Element

Description

System type

Three-phase power system

Load type

Nonlinear load

Nonlinear load structure

Three-phase rectifier with RL load

Filter

Shunt Active Power Filter

Converter

Three-phase voltage-source inverter

Energy-storage element

DC-link capacitor

Grid frequency used for FFT

50 Hz

Conventional control

PI-based control

Proposed control

Neural Network control

Current control

Hysteresis current control

𝐏𝐫𝐨𝐛𝐥𝐞𝐦 𝐖𝐢𝐭𝐡 𝐍𝐨𝐧𝐥𝐢𝐧𝐞𝐚𝐫 𝐋𝐨𝐚𝐝𝐬

Power-electronic loads do not normally draw perfectly sinusoidal current.

Typical nonlinear devices include:

  • Diode rectifiers

  • Controlled rectifiers

  • Variable-speed drives

  • Switching power converters

  • Industrial electronic loads

In the demonstrated system, a three-phase rectifier-based nonlinear load creates a distorted load-current waveform. The distortion is reflected toward the power source when compensation is not provided.    Pasted text

Effects of Current Harmonics

High harmonic current can result in:

  • Distorted source current

  • Poor power quality

  • Increased system losses

  • Additional heating in electrical equipment

  • Interference with nearby loads

  • Increased reactive-power demand

  • Higher Total Harmonic Distortion (THD)

The objective of the Shunt Active Power Filter is therefore to make the source current closer to a sinusoidal waveform.

𝐒𝐡𝐮𝐧𝐭 𝐀𝐜𝐭𝐢𝐯𝐞 𝐏𝐨𝐰𝐞𝐫 𝐅𝐢𝐥𝐭𝐞𝐫

The SAPF behaves as a controlled current-compensation system.

It continuously determines the undesired current components produced by the nonlinear load and injects an appropriate compensating current at the Point of Common Coupling (PCC).

The main hardware section contains:

  • Three-phase inverter

  • DC-link capacitor

  • Grid connection

  • Coupling interface

  • Current measurement

  • Voltage measurement

The inverter is controlled so that the required compensation current is injected into the power system.    Pasted text

𝐖𝐨𝐫𝐤𝐢𝐧𝐠 𝐏𝐫𝐨𝐜𝐞𝐬𝐬

The complete operation can be understood in a few simple stages.

1. Measure Grid Voltage

The three-phase grid voltages are continuously measured.

These measurements are used by the control system to determine the operating condition of the network.

2. Measure Load Current

The nonlinear-load currents are measured.

Since the load contains power-electronic devices, these currents contain harmonic components.

3. Transform the Measured Quantities

The measured three-phase voltage and current signals are converted into a stationary reference frame.

This simplifies:

  • Active-power calculation

  • Reactive-power calculation

  • Reference-current generation

4. Determine Power Components

The controller identifies the required active and reactive power information from the measured voltage and current signals.

A low-pass filtering stage is used to separate the required components.

5. Regulate DC-Link Voltage

The voltage across the SAPF DC-link capacitor is measured and compared with its reference value.

The resulting information is used to determine the additional power required to maintain the DC-link voltage.

6. Generate Compensation Current

Using the calculated power components, the controller determines the required compensation-current reference.

7. Convert Reference Current to Three Phase

The internally calculated compensation signals are converted back into three-phase reference currents.

8. Generate Inverter Pulses

The reference currents are compared with the actual active-filter currents.

A hysteresis current controller produces the switching pulses for the voltage-source inverter.

9. Inject Compensation Current

The inverter injects the required compensating current into the grid.

As a result:

Distorted load current + compensation current → improved source current

This process allows the source current to remain approximately sinusoidal even when the load current contains significant distortion.    Pasted text

𝐍𝐞𝐮𝐫𝐚𝐥 𝐍𝐞𝐭𝐰𝐨𝐫𝐤 𝐂𝐨𝐧𝐭𝐫𝐨𝐥𝐥𝐞𝐫

The important feature of this implementation is the replacement of the conventional controller in the DC-link control stage with a Neural Network controller.

The neural network learns the relationship between selected control inputs and the required controller output.

Neural Network Inputs

The demonstrated training arrangement uses information associated with:

  • DC-link voltage reference

  • DC-link voltage error

Neural Network Target

The required controller output used during training is the control signal associated with the loss-power component of the active-filter controller.    Pasted text

𝐍𝐞𝐮𝐫𝐚𝐥 𝐍𝐞𝐭𝐰𝐨𝐫𝐤 𝐓𝐫𝐚𝐢𝐧𝐢𝐧𝐠

The neural network is trained using data collected from the MATLAB/Simulink model.

Training Procedure

  1. Run the conventional controlled SAPF model.

  2. Record the required input variables.

  3. Store the controller output as target data.

  4. Arrange the collected variables as neural-network training data.

  5. Open the MATLAB neural-network fitting application.

  6. Select input and target data.

  7. Train the network.

  8. Evaluate the regression performance.

  9. Generate the trained neural-network block.

  10. Insert the trained network into the SAPF controller.

  11. Run the complete system again.

  12. Evaluate waveform quality and THD.

The transcript reports regression values close to unity during training, indicating a strong relationship between the network outputs and the target data for the demonstrated dataset.    Pasted text

Reported Neural Network Performance

Training Indicator

Reported Approximate Value

Regression value

Around 0.98–0.99

Desired regression trend

Close to 1

Controller inputs

Reference and error signals

Network purpose

Generate controller output

Implementation

MATLAB neural-network block

𝐂𝐨𝐧𝐭𝐫𝐨𝐥 𝐒𝐭𝐫𝐚𝐭𝐞𝐠𝐲

The overall control sequence is:

Grid Voltage & Load Current

↓

Signal Transformation

↓

Active and Reactive Power Processing

↓

DC-Link Voltage Regulation

↓

Neural Network Controller

↓

Reference Compensation Current

↓

Three-Phase Current Reference

↓

Hysteresis Current Controller

↓

VSI Switching Pulses

↓

Compensation Current Injection

↓

Improved Source Current

This control structure combines conventional active-filter principles with a data-driven controller.

𝐂𝐨𝐧𝐯𝐞𝐧𝐭𝐢𝐨𝐧𝐚𝐥 𝐂𝐨𝐧𝐭𝐫𝐨𝐥 𝐯𝐬 𝐍𝐞𝐮𝐫𝐚𝐥 𝐍𝐞𝐭𝐰𝐨𝐫𝐤 𝐂𝐨𝐧𝐭𝐫𝐨𝐥

The demonstration compares the harmonic performance of a conventional controller and the neural-network-based controller.

Feature

Conventional Controller

Neural Network Controller

DC-link control approach

PI based

Neural Network based

Compensation principle

Active filtering

Active filtering

Inverter current control

Hysteresis

Hysteresis

Nonlinear-load compensation

Yes

Yes

Source-current improvement

Yes

Yes

Reported THD in one FFT setting

1.83%

1.71%

Reported alternate FFT value

About 4.62–4.63%

About 4.53%

The reported simulation therefore shows a small reduction in source-current harmonic distortion when the trained neural-network controller is used. The exact THD value depends on the FFT settings and analysis method selected in MATLAB.    Pasted text

𝐒𝐢𝐦𝐮𝐥𝐚𝐭𝐢𝐨𝐧 𝐑𝐞𝐬𝐮𝐥𝐭𝐬

Without Effective Compensation

The nonlinear load causes:

  • Highly distorted current

  • Significant harmonic components

  • Non-sinusoidal source-current behaviour

With Shunt Active Power Filter

After compensation:

  • Harmonic current is supplied mainly by the active filter

  • Grid-current distortion is reduced

  • Source current becomes closer to sinusoidal

  • Power quality improves

With Neural Network Control

The neural-network-controlled SAPF demonstrates:

  • Effective compensation-current generation

  • Stable operation of the active filter

  • Improved source-current waveform

  • Lower reported THD than the demonstrated conventional-controller case

  • Good neural-network regression performance

𝐓𝐇𝐃 𝐀𝐧𝐚𝐥𝐲𝐬𝐢𝐬

Total Harmonic Distortion (THD) is an important indicator for evaluating the quality of current waveforms.

MATLAB's FFT analysis tool can be used to examine:

  • Fundamental component

  • Individual harmonic orders

  • Harmonic magnitude

  • Frequency spectrum

  • Overall THD

For the 50 Hz analysis shown in the model, the reported neural-network-controlled result reaches approximately 1.71% THD under the selected FFT configuration, compared with approximately 1.83% for the conventional controller.    Pasted text

𝐊𝐞𝐲 𝐅𝐞𝐚𝐭𝐮𝐫𝐞𝐬

  • MATLAB/Simulink-based implementation

  • Three-phase Shunt Active Power Filter

  • Nonlinear rectifier-load compensation

  • Neural Network controller

  • DC-link voltage control

  • Compensation-current reference generation

  • Stationary-reference-frame processing

  • Active and reactive power processing

  • Hysteresis current control

  • Three-phase voltage-source inverter

  • Source-current harmonic mitigation

  • FFT-based harmonic evaluation

  • THD comparison between control approaches

  • Neural-network training and Simulink integration

  • Suitable for understanding intelligent power-quality control

𝐀𝐩𝐩𝐥𝐢𝐜𝐚𝐭𝐢𝐨𝐧𝐬

Neural-network-controlled Shunt Active Power Filters can be studied for applications involving:

  • Industrial power systems

  • Variable-speed-drive installations

  • Power-electronic loads

  • Distribution networks

  • Renewable-energy interfacing systems

  • Smart-grid power-quality studies

  • Harmonic mitigation

  • Reactive-power compensation

  • Intelligent converter control

  • Power-quality research

  • MATLAB/Simulink controller development

𝐋𝐞𝐚𝐫𝐧𝐢𝐧𝐠 𝐎𝐮𝐭𝐜𝐨𝐦𝐞𝐬

By studying this model, learners can understand:

  • Why nonlinear loads generate harmonics

  • How harmonics affect grid current

  • How a Shunt Active Power Filter operates

  • How compensation currents are generated

  • How the DC-link capacitor is regulated

  • How a three-phase inverter injects compensating current

  • How hysteresis current control works

  • How neural-network training data can be obtained from Simulink

  • How a trained neural network can replace a conventional controller

  • How FFT and THD are used to evaluate power quality

𝐖𝐡𝐨 𝐂𝐚𝐧 𝐔𝐬𝐞 𝐓𝐡𝐢𝐬 𝐌𝐨𝐝𝐞𝐥?

This topic is useful for:

  • Electrical engineering students

  • Power-electronics learners

  • Power-quality researchers

  • MATLAB/Simulink users

  • Research scholars

  • Control-system engineers

  • Renewable-energy researchers

  • Engineers studying harmonic compensation

  • Researchers exploring AI-based power-electronic control

𝐂𝐨𝐧𝐜𝐥𝐮𝐬𝐢𝐨𝐧

The Neural Network Control of Shunt Active Power Filter combines intelligent control with conventional power-quality compensation techniques.

A nonlinear load produces distorted current, while the Shunt Active Power Filter injects an appropriate compensating current to improve the source-current waveform. The neural network is trained using controller input-output data and is then incorporated into the MATLAB/Simulink control system.

For the demonstrated operating condition, the neural-network-based approach achieves effective harmonic compensation and shows a reduction in the reported source-current THD compared with the conventional controller.    Pasted text

This simulation provides a clear platform for understanding Shunt Active Power Filters, neural-network control, harmonic compensation, inverter control, THD analysis, and intelligent power-quality improvement.