Neural Network control of grid connected PV system

1 day ago
6 min read

Neural Network control of grid connected PV system


𝐈𝐧𝐭𝐫𝐨𝐝𝐮𝐜𝐭𝐢𝐨𝐧

The Neural Network control of grid connected PV system is a MATLAB/Simulink-based solar photovoltaic system designed to study grid integration, power-quality improvement, MPPT operation, nonlinear loads, and unbalanced load conditions.


Neural Network control of grid connected PV system

Neural Network control of grid connected PV system
₹10,000.00₹5,000.00
Buy Now

The system combines:

  • Solar PV array

  • Incremental Conductance MPPT

  • DC-link capacitor

  • Three-phase Voltage Source Inverter

  • Coupling inductor

  • Neural Network-based load-current estimation

  • Nonlinear load

  • Unbalanced-load testing

  • Grid voltage and current control

A major objective of the control strategy is to maintain a near-sinusoidal grid current even when the connected load current is distorted or unbalanced.    Pasted text

𝐒𝐲𝐬𝐭𝐞𝐦 𝐎𝐯𝐞𝐫𝐯𝐢𝐞𝐰

The simulation represents a grid-connected PV system with neural-network-assisted inverter control.

The PV array is directly connected to the DC side of the Voltage Source Inverter through a DC-link capacitor. The inverter is then interfaced with the three-phase utility grid through a coupling inductor.    Pasted text

Main system components

Component

Function

Solar PV Array

Generates DC electrical power

Incremental Conductance MPPT

Determines the PV reference voltage for maximum power extraction

DC-Link Capacitor

Supports and stabilizes the inverter DC voltage

Voltage Source Inverter

Converts PV DC power into three-phase AC power

Coupling Inductor

Connects the inverter to the AC grid

Neural Network

Estimates the required load-current-related control quantity

Nonlinear Load

Creates distorted load-current conditions

Circuit Breaker

Creates an unbalanced load condition during testing

Grid

Receives active power while the inverter controller supports power quality

𝐏𝐕 𝐀𝐫𝐫𝐚𝐲 𝐂𝐨𝐧𝐟𝐢𝐠𝐮𝐫𝐚𝐭𝐢𝐨𝐧

The transcript describes a PV array formed using 213 W modules, with 20 modules connected in series and 18 parallel strings. The resulting PV array power is approximately 95.9 kW under standard operating conditions.    Pasted text

PV Parameter

Value

Single PV module rating

213 W

Series-connected modules

20

Parallel strings

18

Approximate PV array capacity

95.9 kW

Initial irradiance

1000 W/m²

Reduced irradiance

500 W/m²

Irradiance change time

3 s

Simulation duration

6 s

Unbalanced-load initiation

5 s

𝐖𝐨𝐫𝐤𝐢𝐧𝐠 𝐏𝐫𝐨𝐜𝐞𝐬𝐬

The overall operating sequence is straightforward.

  1. The solar PV array generates DC power according to irradiance and temperature.

  2. PV voltage and current are measured continuously.

  3. The Incremental Conductance MPPT controller processes these measurements.

  4. Instead of directly generating a duty ratio, the MPPT block produces a PV reference voltage.

  5. The DC-link voltage is measured and filtered.

  6. The neural network processes three-phase load-current information.

  7. The inverter reference-current magnitude is generated using PV power, load information, and the DC-link control signal.

  8. Unit-vector signals are used to convert the current magnitude into three-phase sinusoidal reference currents.

  9. The reference currents are compared with the actual inverter currents.

  10. The resulting switching pulses control the Voltage Source Inverter.

  11. The inverter transfers PV power to the AC system while helping improve grid-current quality.    Pasted text

𝐈𝐧𝐜𝐫𝐞𝐦𝐞𝐧𝐭𝐚𝐥 𝐂𝐨𝐧𝐝𝐮𝐜𝐭𝐚𝐧𝐜𝐞 𝐌𝐏𝐏𝐓

The PV side uses an Incremental Conductance MPPT algorithm.

MPPT inputs

  • PV voltage

  • PV current

MPPT output

  • Reference PV voltage

A key detail in this model is that the MPPT output is not directly treated as a converter duty cycle. Instead, voltage limits and voltage increments are used to determine a reference operating voltage for the PV system.    Pasted text

Why this is useful

  • Tracks the PV maximum-power operating region

  • Responds to irradiance variation

  • Provides a reference for the DC-side inverter controller

  • Supports stable PV power extraction during changing environmental conditions

𝐍𝐞𝐮𝐫𝐚𝐥 𝐍𝐞𝐭𝐰𝐨𝐫𝐤 𝐂𝐨𝐧𝐭𝐫𝐨𝐥

The Neural Network is trained using load-current data obtained under different load conditions.

The network receives three-phase load-current information:

  • Phase-A load current

  • Phase-B load current

  • Phase-C load current

Training data are generated from different operating situations including:

  • Normal load condition

  • Nonlinear load condition

  • Unbalanced load condition

After training, the Neural Network produces the load-current-related reference used by the inverter controller.    Pasted text

Neural Network role

The controller helps the inverter recognize changes in load behavior and contributes to the generation of the required reference current.

This makes the inverter capable of operating not only as a renewable-energy interface but also as a power-quality-supporting converter.

𝐂𝐨𝐧𝐭𝐫𝐨𝐥 𝐒𝐭𝐫𝐚𝐭𝐞𝐠𝐲

The inverter control combines several quantities.

Main control inputs

  • PV power

  • Load-current information

  • DC-link voltage

  • Grid/inverter terminal voltage

  • Actual inverter current

The DC-link voltage is passed through a low-pass filter to reduce measurement noise. It is then compared with the desired reference, and a controller processes the voltage error.

The resulting loss-related current component is combined with the load-related and PV-related components to determine the reference current magnitude.    Pasted text

𝐏𝐋𝐋-𝐅𝐫𝐞𝐞 𝐑𝐞𝐟𝐞𝐫𝐞𝐧𝐜𝐞 𝐂𝐮𝐫𝐫𝐞𝐧𝐭 𝐆𝐞𝐧𝐞𝐫𝐚𝐭𝐢𝐨𝐧

An interesting feature of this controller is that the described implementation does not use a conventional Phase-Locked Loop for reference-current generation.

Instead, measured three-phase terminal voltages are used to create normalized unit-vector voltage signals.

These unit vectors are multiplied by the required current magnitude to obtain three-phase sinusoidal current references.    Pasted text

Advantages of this approach

  • Reduces dependence on a conventional PLL stage

  • Generates sinusoidal three-phase reference currents

  • Supports synchronization with the grid voltage

  • Simplifies the reference-current generation structure

  • Works with the neural-network-assisted current controller

𝐏𝐨𝐰𝐞𝐫 𝐐𝐮𝐚𝐥𝐢𝐭𝐲 𝐈𝐦𝐩𝐫𝐨𝐯𝐞𝐦𝐞𝐧𝐭

One of the most important functions of the controller is reducing the influence of a nonlinear load on grid current.

The nonlinear load produces a visibly nonsinusoidal current waveform. Without suitable compensation, this distorted current can deteriorate utility-side power quality.

In the presented model, the PV inverter controller attempts to compensate for this behavior so that the grid current remains sinusoidal even though the load current is distorted.    Pasted text

Control objective

Distorted load current → Neural Network and inverter control → Improved grid current

This demonstrates that the inverter can simultaneously perform:

  • PV power transfer

  • Grid current regulation

  • Harmonic compensation

  • Load disturbance compensation

  • Power-quality improvement

𝐓𝐞𝐬𝐭 𝐂𝐨𝐧𝐝𝐢𝐭𝐢𝐨𝐧𝐬

The model is tested under multiple operating scenarios.    Pasted text

Operating Condition

Test Description

Normal operation

PV supplies power while the grid-connected inverter operates normally

Irradiance variation

Irradiance changes from 1000 to 500 W/m²

Nonlinear load

Distorted load current is introduced

Unbalanced load

One load phase is disconnected

MPPT test

PV operating point changes with irradiance

Power-quality test

Grid current is monitored under distorted load conditions

𝐈𝐫𝐫𝐚𝐝𝐢𝐚𝐧𝐜𝐞 𝐕𝐚𝐫𝐢𝐚𝐭𝐢𝐨𝐧 𝐓𝐞𝐬𝐭

Initially, the PV system operates at an irradiance of 1000 W/m².

The MPPT controller moves the PV system toward its maximum-power operating point during the initial transient.

At approximately 3 seconds, the irradiance is reduced to 500 W/m².    Pasted text

Observed response

  • PV current decreases significantly.

  • PV power reduces as solar irradiance decreases.

  • PV voltage experiences a temporary change.

  • The MPPT controller searches for the new operating point.

  • The PV system settles at the new available power level.

The transcript reports PV maximum power at the higher irradiance at roughly 95.7 kW.    Pasted text

𝐍𝐨𝐧𝐥𝐢𝐧𝐞𝐚𝐫 𝐋𝐨𝐚𝐝 𝐂𝐨𝐧𝐝𝐢𝐭𝐢𝐨𝐧

During nonlinear-load operation, the load current becomes distinctly nonsinusoidal.

However, the grid-side current remains much closer to a sinusoidal waveform because of the inverter control strategy.    Pasted text

Quantity

Observed Behaviour

Load current

Distorted / nonsinusoidal

Grid current

Maintained near sinusoidal

Inverter current

Controlled by reference-current strategy

PV system

Continues supplying available solar power

Controller

Compensates for load-related current distortion

𝐔𝐧𝐛𝐚𝐥𝐚𝐧𝐜𝐞𝐝 𝐋𝐨𝐚𝐝 𝐂𝐨𝐧𝐝𝐢𝐭𝐢𝐨𝐧

The unbalanced load condition is introduced at approximately 5 seconds by disconnecting one of the load phases.    Pasted text

This creates a sudden disturbance in the electrical system.

Observed effects

  • Temporary oscillation in PV voltage

  • Temporary disturbance in PV current

  • Temporary reduction in PV power

  • Recovery toward the previous operating region

  • Grid current remains controlled

  • Inverter current continues to maintain a sinusoidal characteristic

The transcript indicates that the system requires approximately 0.3 seconds to return toward the normal operating condition after the unbalanced-load disturbance.    Pasted text

𝐒𝐢𝐦𝐮𝐥𝐚𝐭𝐢𝐨𝐧 𝐑𝐞𝐬𝐮𝐥𝐭𝐬

The MATLAB/Simulink model monitors several important electrical variables.

PV-side results

  • Solar irradiance

  • PV temperature

  • PV voltage

  • PV current

  • PV power

  • Maximum-power tracking response

DC-side results

  • DC-link capacitor voltage

  • DC-link transient response

AC-side results

  • Grid voltage

  • Grid current

  • Inverter voltage

  • Inverter current

  • Load voltage

  • Load current

Overall result interpretation

The simulation demonstrates that:

  • Incremental Conductance MPPT tracks changes in solar conditions.

  • PV power responds correctly to irradiance reduction.

  • Nonlinear load current contains distortion.

  • The inverter control reduces the influence of this distortion on the grid.

  • The neural-network-assisted controller responds to normal, nonlinear, and unbalanced load conditions.

  • Grid and inverter currents remain substantially more sinusoidal during the tested disturbances.    Pasted text

𝐊𝐞𝐲 𝐅𝐞𝐚𝐭𝐮𝐫𝐞𝐬

  • 𝐍𝐞𝐮𝐫𝐚𝐥 𝐍𝐞𝐭𝐰𝐨𝐫𝐤-assisted inverter control

  • 𝐆𝐫𝐢𝐝-𝐜𝐨𝐧𝐧𝐞𝐜𝐭𝐞𝐝 solar PV operation

  • 𝐈𝐧𝐜𝐫𝐞𝐦𝐞𝐧𝐭𝐚𝐥 𝐂𝐨𝐧𝐝𝐮𝐜𝐭𝐚𝐧𝐜𝐞 MPPT

  • Approximately 𝐏𝐕 𝐚𝐫𝐫𝐚𝐲 𝐜𝐚𝐩𝐚𝐜𝐢𝐭𝐲 𝐨𝐟 𝟗𝟓.𝟗 𝐤𝐖

  • Nonlinear-load compensation

  • Unbalanced-load testing

  • DC-link voltage regulation

  • Three-phase inverter current control

  • Unit-vector-based reference-current generation

  • No conventional PLL used for the described reference-current generation

  • PV irradiance-change analysis

  • Grid-current power-quality improvement

  • MATLAB/Simulink implementation

𝐀𝐩𝐩𝐥𝐢𝐜𝐚𝐭𝐢𝐨𝐧𝐬

This simulation is useful for studying:

  • Grid-connected photovoltaic systems

  • Artificial Neural Network-based power-electronic control

  • Renewable-energy integration

  • Smart inverter control

  • Solar PV power-quality enhancement

  • Harmonic mitigation

  • Nonlinear-load compensation

  • Unbalanced-load analysis

  • MPPT controller performance

  • Three-phase Voltage Source Inverters

  • Intelligent control of renewable-energy converters

  • MATLAB/Simulink-based power-system research

𝐖𝐡𝐨 𝐂𝐚𝐧 𝐔𝐬𝐞 𝐓𝐡𝐢𝐬 𝐌𝐨𝐝𝐞𝐥?

The topic is particularly useful for:

  • Electrical engineering students

  • Power electronics learners

  • Renewable-energy researchers

  • MATLAB/Simulink users

  • Power-system researchers

  • Engineers working with PV inverters

  • Researchers studying Neural Network control

  • Researchers working on grid power quality

𝐂𝐨𝐧𝐜𝐥𝐮𝐬𝐢𝐨𝐧

The Neural Network control of grid connected PV system demonstrates an intelligent approach for integrating solar photovoltaic power with the utility grid while improving current quality.

The system combines Incremental Conductance MPPT, Neural Network-based load-current processing, DC-link voltage regulation, unit-vector reference generation, and three-phase inverter control.

Simulation results described in the source show that the system can respond to irradiance variation, nonlinear loading, and unbalanced loading while maintaining controlled grid and inverter currents. This makes the model a useful platform for understanding AI-assisted renewable-energy control and grid power-quality improvement in MATLAB/Simulink.    Pasted text